| Support Looper's Delight!! |
|||||
|
|
|||||||||||||||||
|
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] Re: Electro Harmonix help
Yes Charles thats what I tried.
As soon as both legs are connected the foot controller goes blank. The foot controller is connected in parallel with the two delays. The second delay has the ground connected to the foot controller and the tip is separated by the .1 bypass cap. Bill From: Charles Zwicky <cazwicky@earthlink.net> To: Loopers-Delight@loopers-delight.com Sent: Tue, 26 Feb 2008 7:24 pm Subject: Re: Electro Harmonix help Just to make sure that I am perfectly clear with how you rigged
this... you have one foot controller split to two EH-16 delays, and
you have inserted a 0.1µf in series with the 'tip' connection to one
of the EH-16 and the 'ring' connection is still making full contact
with that EH-16??
Charles, #AOLMsgPart_2_66521cb6-3b3d-48f6-ba3e-a94f177f96e3 Try isolating the 'tip' connector with a capacitor (.01µf or larger should do) on the cable to ONE of the units... this will block the DC but allow the serial data to pass....
-- ... More new features than ever. Check out the new AOL Mail! --
|
||||||||||||||||
|
Looper's Delight Home | Looper's Delight Mailing List Info This page is maintained by Kim Flint contact us |
||||||||||||