RE: echoplex problem
It's very unusual for the fuse to blow in an EDP; I've never had it
happen, (well over 1000 units). How old is it? Is it pre-1998 without
the 5V supply conversion? Did you replace it with a 'Timed' or
'Slow-blow' fuse, these are usually marked T250mA? A fast-blow, marked
'F' can blow on start-up. Did both these fuses blow while you were using
it or at start-up?
Intermittent fuse failure is usually indicative of either a failing
component, likely to be in the power-supply, or a dry solder joint that
arcs and causes carbon build-up; again likely to be in the supply:
transformer & voltage regulators.
Send me more info and I'll try to help further,
Regards,
Andy.
-----Original Message-----
From: Mark Cook [mailto:markwaynecook@yahoo.com]
Sent: 09 May 2003 13:52
To: Loopers-Delight@loopers-delight.com
Subject: echoplex problem
Hi,
The fuse in my echoplex recently blew. After a couple of days the new
fuse blew. Does anyone know what the problem might be?
Thanks.
Mark